EMI/RFI POWER LINE FILTERS Adam Technologies, Inc. METAL CASE PCB MOUNT PLF SERIES .984 [25.00] .236 [6.00] PLF-3PC .315 [8.00] .984 [25.00] .315 [8.00] DIM "A" PLF-1PC .590 [15.00] PLF-2PC .787 [20.00] PLF-3PC .787 [20.00] PLF-6PC .787 [20.00] .630 [16.00] A L mH PART NUMBER PLF-1PC PLF-2PC PLF-3PC PLF-6PC RATED VOLTAGE 250V AC 250V AC 250V AC 250V AC RATED CURRENT 1 AMP 2 AMP 3 AMP 6 AMP GROUND CAPACITANCE 2.2 nF 2.2 nF 2.2 nF 3.3 nF LEAKAGE CURRENT 0.5mA MAX. 0.5mA MAX. 0.5mA MAX. 0.5mA MAX. L L Cx Cy G N Cx N L mH CIRCUIT DIAGRAM Insertion Loss in dB (Measured in 50 systems, as IEC / cispr No. 17) PLF-1PC PLF-1PC 100 90 80 100 90 80 PLF-2PC PLF-2PC 70 60 50 40 30 20 10 0 0.15 0.2 0.4 0.6 1 2 4 Frequency (MHz) 6 8 10 20 30 CM DM 70 60 50 40 30 20 10 0 0.15 0.2 0.4 0.6 1 2 4 Frequency (MHz) 6 8 10 20 30 CM DM PLF-3PC PLF-3PC 100 90 80 100 90 80 PLF-6PC PLF-6PC 70 60 50 40 30 20 10 0 0.15 0.2 0.4 0.6 DM 1 2 4 Frequency (MHz) 6 8 10 20 30 CM 70 60 50 40 30 20 10 0 0.15 0.2 0.4 0.6 DM CM 1 2 4 Frequency (MHz) 6 8 10 20 30 LOAD LINE Cy 909 Rahway Avenue * Union, New Jersey 07083 * T: 908-687-5000 * F: 908-687-5710 * WWW.ADAM-TECH.COM Attenuation (dB) Attenuation (dB) Attenuation (dB) Attenuation (dB) 163 |